25% Rabatt på Dynaudio Emit! - Prisvärda & stilrena

Innehållet kan inte visas

Shunyata Hydra Delta D6 (240V)

Transparent strömrenare med hög dämpfaktor
51 490 kr
Lägsta priset senaste 30 dagarna
51 490 kr
204_orig_150_kortbetalning11.png
204_swish_logo.png
204_150_faktura41.png
branschvinnare_2023.png
Lägg i varukorgen
Mer produktinformation
Leverantörslager (Vanligtvis 2-6 arbetsdagar om varan finns tillgänglig hos leverantören)
Fri frakt vid köp över 500 kr! (Gäller ej begagnat)
Garanti i 24 månader

Shunyata Research Hydra Delta D6

The Delta D6 power distributor provides compelling proof of Shunyata Research’s commitment to delivering state-of-the-art performance at an affordable price. The Delta D6 deservedly takes it place in the Performance Line of power distributors.

For the first time Shunyata Research has incorporated its finest, most exclusive technologies into a package priced so affordably that it will redefine value well beyond its price.

The Delta D6’s unheard of combination of measurable noise reduction, patented science and exclusive parts will be impossible to find outside of Shunyata Research’s meticulously hand-crafted line of reference power distributors.

True to form, Shunyata Research wasted no time in applying its finest patented technologies and performance features – previously available only in Hydra Triton v2 and Denali models – into the affordable Delta D6 outlet model.

In addition to offering enough outlets to power any complex system, the Delta D6 delivers a staggering > 40dB @ 1mHz. By any standard the performance of this unit represents a new benchmark for performance at and well beyond its retail price.

The Delta D6 deliver all this performance along with Shunyata Research’s signature DTCD® (Dynamic Transient Current Delivery) technology, allowing it to be paired with an unlimited variety of electronics including high-current amps, projectors, digital front ends and entire systems.

The unit comes equipped with Shunyata Research’s finest Trident-Defense protection system.

APPLICATIONS

The Delta D6 has six outlets. The unit has no limitations with DTCD® (instantaneous current) and is rated at 16A on EU/UK models. All outlets are extremely high-current capable.
The Delta D6 will deliver reference-caliber performance for all systems, whether primarily film, music, sound or recording.

Raising the bar for performance, value and customer satisfaction has been the driving force behind the design of Shunyata Research’s products for 20 years. The Delta D6 is the embodiment of Shunyata Research’s enormous progress toward those ideals.

DTCD® DESIGNED (Dynamic Transient Current Delivery)

The Delta D6 was designed using Shunyata Research’s DTCD® analyzer. DTCD® Analysis measures instantaneous current through extremely-low impedance electrical conductors and contacts. Shunyata Research uses it to optimize the design and performance of our power conditioners and power cabling.

CCI™ NOISE REDUCTION

Traditional power conditioners are designed to block incoming noise from outside the home but they do not address the noise that is generated by the electronic components themselves. In fact, most conditioners reflect noise back into other components connected to the power conditioner. CCI™ (Component-to-Component Interference) is one of the most significant but often overlooked aspects to power system performance. Shunyata’s CCI™ filter consists of a proprietary multi-stage filter that reduces electrical noise and power supply generated interference.

NIC™ NOISE REDUCTION

The NIC™ (Noise Isolation Chamber) is a patented technology that reduces high-frequency power line noise. NICs™ use ferroelectric substances that actually absorb high-frequency noise. This allows the Delta D6 power distributor to reduce noise without any of the negative interactions associated with conventional power conditioner designs.

[ US Patent: 8,658,892 ]

GP-NR NOISE REDUCTION

When it comes to reducing noise, engineers focus primarily on the AC electrical lines, with little if any thought given to the ground lines. The incoming ground line and the internal power conditioner ground plane can actually act as antennae, drawing in electrical noise that may interfere with the operation of the connected components. Ground Plane Noise Reduction is a proprietary technology developed by Shunyata Research to significantly reduce interference caused by this phenomenon, thereby providing a more pure audio experience.

HIGH CURRENT CAPABILITY

The Delta D6 is rated at a full 20 Amps of continuous current (16 Amps on EU/UK models), ensuring unfettered power delivery to complex entertainment systems, including those with high-powered amplifiers. Advanced electromagnetic breakers in addition to massive buss and 8-gauge ArNi® conductors provide exceptional dynamic contrast and bass impact.

HYDRAULIC ELECTROMAGNETIC BREAKER

Common power conditioners use fuses or thermal breakers for over-current protection. When heavily loaded, they may cause voltage drops, increased contact impedance, thermal noise, excessive heat generation, and current-limiting effects. The Delta D6 uses a more advanced solution called a hydraulic electromagnetic breaker that operates right up to the maximum current rating without the limitations of fuses or thermal breakers.

HIGH-QUALITY OUTLETS

The US and Asian model Delta D6 power distributors include Hubbell outlets that use a triple-wipe contact system and have broad contact areas to grip a plug from three different sides, providing superior electrical integrity. Hubbell outlets feature a solid brass back-strap that ensures a reliable ground connection that may reduce noise and hum. The European & UK model Delta D6’s includes Euro or UK-style mains sockets that feature alloy contacts designed to accept large-gauge conductors.

ArNi® CONDUCTORS

Shunyata Research has developed a proprietary line of ArNi® conductors. They are made from certified OFE C10100 (Certified ASTM F68) copper. The wire strands are arrayed in a unique hollow tube VTX™ geometry that reduces skin effects. ArNi® conductors are treated with Shunyata Research’s exclusive Kinetic Phase Inversion Process (KPIP™) for a period of 8 days.

VIBRATION MANAGEMENT

Mechanical vibration can be very destructive to system performance. The Delta D6 was designed from its inception to include advanced forms of vibration control that improve the recovery of subtle musical detail and nuance. All chassis panels and internal structures are treated with vibration-dampening materials. The outlets are isolated from the chassis with vibration-dampening gaskets that reduce vibration conducted through the AC cables. All internal modules, filters, and electronics are encapsulated in a vibration-absorbent compound.

KPIP™ “BLACKBIRD” PROCESSOR

Each Delta D6 is treated with Shunyata Research’s proprietary Kinetic Phase Inversion Process (KPIP™). The KPIP™ dramatically reduces burn-in time and significantly improves sonic performance.

CRYOGENIC TREATMENT

Many of the electrical components in the Delta D6 are treated in Shunyata Research’s own advanced computer-controlled cryogenics lab. Further cryogenic treatment of the unit is strongly discouraged, and will void your warranty.

VIBRATION-DAMPENING FOOTER

The Delta D6 comes standard with Shunyata Research’s vibration-dampening footers. Power distributors react very similarly to amplifiers in relationship to floor-borne vibration. Shunyata Research’s footers were specifically designed to reduce vibration from the supporting platform.
The footers may be optionally upgraded to SSF-38 stainless steel footers. After researching multiple forms of energy dissipation methods, Shunyata Research developed the SSF-38 to provide the performance characteristics of an expensive after-market isolator but at a fraction of the cost.

Specifikationer:

MAXIMUM VOLTAGE

  • 90-125 VAC r.m.s. unregulated (US)
  • 220-240 VAC r.m.s. unregulated (EU, UK, ASIA)

INPUT CURRENT RATINGS

  • US/Asia maximum continuous current: 20A
  • Euro/UK maximum continuous current: 16A

OUTPUT CURRENT RATINGS

  • US/Asia max current/outlet: 15A
  • Euro/UK max current/socket: 16A

TRANSIENT SUPPRESSION

  • Maximum transient protection: 40,000 A @ 8/50 μ

OVER-CURRENT PROTECTION

  • Hydraulic electromagnetic breaker

NOISE SUPPRESSION

  • Input to Output (100 kHz – 30 MHz): > 40 dB reduction
  • Outlet to outlet (100 kHz – 30 MHz): > 50 dB reduction

OUTLETS & CONNECTORS

  • Inlet: IEC C19R
  • US outlets: 6 NEMA 5-20R
  • AS outlets: 6 NEMA 5-20R
  • EU sockets: 6 CEE 7/3
  • UK sockets: 6 UK1-13R

WIRING SYSTEM

  • 8 gauge ArNi® VTX Buss system
  • 10 gauge ArNi® VTX outlet wiring
  • Ratings: 600 V 105° C

VIBRATION CONTROL

  • Vibration dampening panels (internal)
  • AC outlet dampening gaskets
  • Shunyata Isolation Footer (standard)
  • Shunyata Isolation SSF-38 Footer (optional)

CONSTRUCTION

  • All aluminum chassis
  • Anodized, brushed aluminum faceplate

DIMENSIONS

  • Width: 17 inches (43.2 cm)
  • Depth: 9 inches (22.9 cm)
  • Height: 4.6 inches (11.7 cm)
  • Weight: 9.5 lbs (4.31 kg)
Modell
Hydra Delta D6 (240V)
Artikelnummer
9146_SHU00224
Varumärke
Jämför produkt